141
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Planning
5
5.6.5 Example 5: Two-
zone
system with integrated domestic hot water tank
All in One unit in two-zone conguration (“B”), High Performance, 3/5 kW
RT1
RT2
H4[E33]
H8
H2b
T
PAW-A2W-TSOD [E36]
H5
H11
H11
H6
H9 [E53/E41]
H9 [E54/E40]
H7
Ø12,7 mm
R32
G
L
0,90 kg
20 g/m
>10 m
WH-ADC0309J3E5B
HxWxD (mm)
1800x598x717
kg
122
H21
H23
H22
H10
Ø 6,35 mm
230 V [E62]
230 V [E61]
WH-UD0*JE5 [3-5 kW]
H1
H3
HxWxD (mm)
622x824x298
kg
37
[E63]
NL NL
3
21
C
PAW-A2W-TSOD
PAW-A2W-TSHC
PAW-A2W-TSRT
O N C O N C N LH
AC 230 V
N O C
AC 230 V
N C HLN C HL
CZ-TK1
AC 230 V
PAW-A2W-TSRT
E27
E28
E33
E34
E35
E36
E40
E41
E44
E46
E48
E49
E50
E51
E53
E54
E57
E59
E61
E63
E60
E62
H11
E26
E61
E62

Table of Contents