EasyManua.ls Logo

Panasonic Aquarea WH-SDC16H6E5 - Series

Panasonic Aquarea WH-SDC16H6E5
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
ATTENTION
Danger of water pipes freezing in outside temperatures below 0 °C
Once the heating circuit of a mono-bloc system is lled with water and the outside temperature falls
below 0 °C, there is a risk that the water pipes may freeze up. This can cause a lot of damage to
the device.
The client should therefore ensure the absence of frost by taking one of the following measures:
Operate the heating circuit using a food-safe antifreeze mixture (propylene glycol).
Provide an additional cabinet heating in the mono-bloc unit, to prevent the heating circuit
from freezing up.
Drain the water from the heating circuit with eld-supplied equipment (manually or
automatically) before freezing starts.
4.5.2 Series
The Aquarea heat pump system has three di󰀨erent series that are in turn available in multiple
model variants. An overview of the complete range can be found at the beginning of this manual
(→ 1 Model range, p. 8).
With the large number of di󰀨erent model variants, which illustrates the large variety of
characteristics and functions of the Aquarea heat pumps, Panasonic can achieve a high level of
exibility and adaptability for the most varied applications. This is intended to o󰀨er the best possible
solution to address individual heat supply and air-conditioning requirements for buildings using
Aquarea heat pumps.
The following table shows the Aquarea heat pump series and their key characteristics in the context
of typical applications.
Overview of Aquarea series and model variants
Aquarea High Performance Aquarea T‑CAP Aquarea HT
Heating - Cooling - DHW Heating - Cooling - DHW Heating - DHW
Single phase from 3 to 16 kW
Three phase from 9 to 16 kW
Single phase from 9 to 12 kW
Three phase from 9 to 16 kW
Single phase from 9 to 12 kW
Three phase from 9 to 12 kW
Connectable to
Radiators-Fancoil-Underoorheating-DHW Radiators-Fancoil-Underoorheating-DHW Traditional high-temperature radiators - DHW
Application
Normal installation For extreme cold ambient Retrotforoldradiators
Energy efciency
A+++
A++
A++ A++ A++ A++
Heating 35 °C / 55 °C
1
Heating 35 °C / 55 °C
1
Heating 35 °C / 55 °C
1
Minimum outdoor temperature
-20 °C
-28 °C (All in One and Bi-bloc)
-20 °C (Mono-bloc)
2
-20 °C
Minimum outdoor temperature to provide constant capacity at 35 °C supply water temperature
-7 °C (not for all units) -20 °C
2
-15 °C
Supply temperature for heating. Maximum / Heat pump only
75 °C
3
/ 55 °C
4
(or 60 °C for Aquarea
J Generation)
75 °C
3
/ 60 °C
4
(65 °C
5
for Aquarea
J Generation)
75 °C
3
/ 65 °C
13.04.2021, cH
- text shortened and rearranged in a dierent, more
stringent sequence
- new table inserted from EU-GCAT.A2W21

Table of Contents

Related product manuals