139
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Planning
5
5.6.3 Example 3: Single-phase two-zone system
Hydrokit, High Performance, 7/9 kW, domestic hot water tank
WH-UDxxJE5(-1) [7-9 kW]
Ø15,88
Ø 6,35
WH-SDC0709J3E5
[7-9 kW]
H3
H2
H1
CZ-NS4P
H12 [E39]
T
PAW-A2W-TSOD [E36]
RT1
RT2
H10
H4
H23
H22
H21
PAW-TDxxC1E5(-UK)
H24
H8
H5
H11
H11
H7
H25 [E28]
H6
H14 [E58]
H9 [E53]
H9 [E54]
H13[E52]
PAW-A2W-TSHC [E45]
PAW-A2W-TSHC [E44]
M
M
NL NL
3
21
E61
E63
E60
E62
C
PAW-A2W-TSOD
PAW-A2W-TSHC
PAW-A2W-TSHC
PAW-A2W-TSRT
O N C O N C N LH
AC 230 V
N O C N O C
AC 230 V
N C HLN C HL
CZ-TK1
AC 230 V
PAW-A2W-TSRT
E27
E28
E30
E33
E34
E35
E36
E38
E40
E41
E44
E45
E46
E48
E49
E50
E52
E53
E54
E57
AC 230 V
E58
CZ-NS4P
E39
E26

Table of Contents