EasyManua.ls Logo

Panasonic Aquarea WH-SXC09H3E5 - Outdoor Units and Mono-Bloc Units

Panasonic Aquarea WH-SXC09H3E5
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
153
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Installation
6
Hydrokit J or H generation
55
200
756
1556
07 061
> 375 > 375
1 2 3
45
1
1 Wall
2 Top mounting plate
3 Hexagon screw M8 with washer
4 Hydrokit
5 Bottom mounting plate
6 Hooks
7 Slots
8 Phillips head screw
1
2
6
5
7
5
8
6.4.2 Outdoor units and mono-bloc units
Carry out the following steps to install the outdoor unit or mono-bloc unit:
1. Exercise caution when unpacking the device at the installation site.
2. Attach the device to a concrete foundation or a strong ground frame by means of four anchor
bolts as shown in the illustration (see below) e.g. on the outer wall of a building. Ensure
horizontal alignment of the device. Also observe the instructions in the sections on attaching
the devices (→ 5.2.2.3 Securing the outdoor unit, p. 102, → 5.2.3.3 Securing the mono-bloc
unit, p. 111).

Table of Contents