EasyManua.ls Logo

Panasonic Aquarea WH-SXC09H3E5 - Page 50

Panasonic Aquarea WH-SXC09H3E5
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Bi-bloc systems | Aquarea T-CAP | H Generation | Three Phase | Super Quiet | Heating and Cooling | R410A
Three phase (Power to indoor)
Kit KIT‑WQC09H3E8 KIT‑WQC12H9E8 KIT‑WQC16H9E8
Heating capacity / COP (A +7 °C, W 35 °C) kW / – 9.00 / 4.84 12.00 / 4.74 16.00 / 4.28
Heating capacity / COP (A +7 °C, W 55 °C) kW / – 9.00 / 2.94 12.00 / 2.88 16.00 / 2.71
Heating capacity / COP (A +2 °C, W 35 °C) kW / – 9.00 / 3.59 12.00 / 3.44 16.00 / 3.10
Heating capacity / COP (A +2 °C, W 55 °C) kW / – 9.00 / 2.21 12.00 / 2.19 16.00 / 2.13
Heating capacity / COP (A -7 °C, W 35 °C) kW / – 9.00 / 2.85 12.00 / 2.72 16.00 / 2.49
Heating capacity / COP (A -7 °C, W 55 °C) kW / – 9.00 / 2.02 12.00 / 1.92 16.00 / 1.86
Cooling capacity / EER (A 35 °C, W 7 °C) kW / – 7.00 / 3.17 10.00 / 2.81 12.20 / 2.57
Cooling capacity / EER (A 35 °C, W 18 °C) kW / – 7.00 / 5.19 10.00 / 5.13 12.20 / 3.49
ErP data for Space Heating
Average climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 181 / 130 170 / 130 160 / 125
SCOP W35 / W55 4.59 / 3.32 4.32 / 3.32 4.08 / 3.20
Energy class
1
W35 / W55 A+++ / A++ A++ / A++ A++ / A++
Warm climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 235 / 158 231 / 158 231 / 159
SCOP W35 / W55 5.95 / 4.02 5.86 / 4.02 5.86 / 4.05
Energy class
1
W35 / W55 A+++ / A+++ A+++ / A+++ A+++ / A+++
Cold climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 160 / 125 160 / 125 150 / 125
SCOP W35 / W55 4.08 / 3.20 4.08 / 3.20 3.83 / 3.20
Energy class
1
W35 / W55 A++ / A++ A++ / A++ A++ / A++
Indoor unit WH‑SQC09H3E8 WH‑SQC12H9E8 WH‑SQC16H9E8
Sound pressure Heat / Cool dB(A) 33 / 33 33 / 33 33 / 33
Dimension H x W x D mm 892 x 500 x 340 892 x 500 x 340 892 x 500 x 340
Net weight kg 43 44 45
Water pipe connector Inch R 1¼ R 1¼ R 1¼
A class pump
Number of speeds Variable Speed Variable Speed Variable Speed
Input power (Min / Max) W 32 / 102 34 / 110 30 / 105
Heatingwaterow(∆T=5K.35°C) l/min 25.8 34.4 45.9
Capacity of integrated electric heater kW 3 9 9
Recommended fuse A 15 / 30 15 / 30 15 / 30
Recommended cable size, supply 1 / 2 mm² 5 x 1.5 / 3 x 1.5 5 x 1.5 / 5 x 1.5 5 x 1.5 / 5 x 1.5
Outdoor unit WH‑UQ09HE8 WH‑UQ12HE8 WH‑UQ16HE8
Sound power
2
Heat dB(A) 58 58 62
Dimension H x W x D mm 1,410 x 1,283 x 320 1,410 x 1,283 x 320 1,410 x 1,283 x 320
Net weight kg 151 151 161
Refrigerant (R410A) / CO
2
Eq. kg / t 2.85 / 5.951 2.85 / 5.951 2.99 / 6.243
Pipe diameter Liquid / Gas Inch (mm) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20
Pipe length for additional gas m 10 10 10
Additional gas amount g/m 50 50 50
Operation range
Outdoor ambient
Heat °C -28 ~ +35 -28 ~ +35 -28 ~ +35
Cool °C +16 ~ +43 +16 ~ +43 +16 ~ +43
Water outlet
Heat °C 20 ~ 60 20 ~ 60 20 ~ 60
Cool °C 5 ~ 20 5 ~ 20 5 ~ 20
1 Scale from A+++ to D.
2 Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7 °C.
Note:
EER and COP calculation is based in accordance to EN14511.

Table of Contents

Related product manuals