76 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
2
3
1
4
A
5
6
7
A Internal view
1 Thermometer
2 Cover of electric tank heater (Ø 180 mm)
3 Adjustable foot (x 3, 120° angle)
4 Sacricialmagnesiumanode
5 Heat insulation (50 mm thick)
6 Hot water tank
7 Heat exchanger coil
PAW‑TA20C1E5STD / PAW‑TA30C1E5STD / PAW‑TA40C1E5STD
Connections
a
d
b
e
c
f
B
2
1
b
c d
e
f
A
a
A Top view for oor-standing installation
1 Detail view of water piping connections on top side
B Bottom view for wall‑mounted installation
2 Detail view of water piping connections on bottom side
Connection PAW‑TA15C1E5STD
a Air purge outlet G 1/2”
b Hot water outlet G 3/4”
c Return water outlet to the heat pump G 3/4”
d Fresh water inlet G 3/4”
e Supply water inlet from the heat pump G 3/4”
f Circulation pipe inlet G 3/4”
Unit: Inches (")
PAW‑TA15C1E5STD
a
A
c
b
d
e
f
Connection
PAW
TA20C1E5STD
PAW
TA30C1E5STD
PAW
TA40C1E5STD
a Thermometer G 1/2” G 1/2” G 1/2”
b Hot water outlet G 1” G 1” G 1”
c Supply water inlet
from the heat pump
G 1” G 1” G 1”
d Circulation pipe inlet G 3/4”
(160 – 400 l),
G 1” (500 l)
G 3/4”
(160 – 400 l),
G 1” (500 l)
G 3/4”
(160 – 400 l),
G 1” (500 l)
e Return water outlet to
the heat pump
G 1” G 1” G 1”
f Fresh water inlet G 1” G 1” G 1”
Unit: Inches (")