Preset scope
[Mode A, Mode B, Mode C]
Selected here are the setting items to be recalled when the contents of the preset memory are regenerated.
Mode A Pan, Tilt, Zoom (including digital zoom), Focus, Iris, Gain, white balance adjustment value
Mode B Pan, Tilt, Zoom (including digital zoom), Focus, Iris
Mode C Pan, Tilt, Zoom (including digital zoom), Focus
[Note]
When registering a preset position, all values are saved.
When recalling a registered preset position, there are certain operation procedures to undergo beforehand so that
each value can come into effect:
[Focus]
Firstly, enable manual focus. Then, the focus value of the recalled preset position can come into effect.
[Iris]
Firstly, enable manual iris. Then, the iris value of the recalled preset position can come into effect.
[Gain]
Firstly, set Gain between 0 dB~42 dB. Then, the Gain value of the recalled preset position can come into effect.
[White Balance Mode]
Firstly, set White Balance Mode as AWB A or AWB B. Then, the White Balance Mode value of the recalled preset
position can come into effect.
Factory settings: Mode A