Panasonic Solar Cells Handbook, Page 11 August 1998
SUNCERAM II CELL FOR OUTDOOR USE - CONTINUED
3.4. Specification Table for Outdoor Use
Model No.
Dime ns ions (mm)
t =1.4mm (Max.)
light source AM=1.5 : 100mW/cm
Operating
voltage Vp
(V)
Operating current Ip
(mA)
Open-circuit voltage
Voc (V)
Short-circuit current
Isc (mA)
Ave rage Ave rage Ave rage
BR-243318C 24.0X33.0
1.8
16.4 3.45 17.5
BR-246618C 24.0X66.0 35.0 2.80 39.0
BR-242221C 24.0X22.0 2.1 6.6 4.15 7.0
BP-372234C 37.0X22.0
3.4
8.5 5.50 9.0
BP-373334C 37.0X33.0 14.5 5.50 15.5
BP-376634C 37.0X66.0 31.5 5.50 33.0
BR-378234C 37.0X82.0 40.0 5.50 43.0
BR-160334C 165.0X27.0 650 5.50 71.5
BR-748264C 74.0X82.0 6.4 40.0 11.0 43.0
BR-111108C 110.0X110.0 8.0 76.0 12.0 84.0
BR-160416C 162.5X41.0
16.0
19.1 24.0 20.5
BP-160516C 162.5X48.0 22.1 24.0 23.5
BR-160716C 162.5X73.0 34.0 24.0 36.0
Note 1) Measurement temperature 25
°
C (77
°
F)
Note 2) Light source and intensity are specified by Panasonic’s standard.
Note 3) Standard units come with copper electrodes.
3.5. Dimensions (Outdoor use) thickness: 1.1(maxl.4) ___________________________________ Unit: mm
(1.4)
(6.0)
16.6 0.3
+
-
162.5 0.3
+
-
BP-160716C
(1.4)
(6.0)
37.0 0.3
(1.6)
66.0 0.3
(6.0)
+
-
+
-
BP-376634C