48
Main Menu (continued)
49
CONTROL
Underlined values indicate factory defaults.
Submenu Setting Description
CONTROL
LOCAL
REMOTE
Selects operation. (with control lock)
[LOCAL] Front panel operation is enabled (including controls that use the GPI
function)
[REMOTE] Remote operation enabled (controls using RS-232C or RS-485. Front
panel operation is locked)
Power On/Off, VOLUME operations, GPI control and menu dis-
play are available when the lock is engaged.
Only [CONTROL]/[LOCAL ENABLE] menu items are available
when the lock is engaged.
The rotary knob <PICTURE> cannot be used to change set val-
ues when the lock is engaged.
The [LOCAL ENABLE] setting determines operations in lock
mode.
The
mark appears in the operation status display, menu
display ([MAIN MENU] (main menu), [FUNCTION] menu, [IN-
PUT SELECT] menu), [PICTURE] (picture adjusting) menu, and
FUNCTION display screens when the lock is engaged.
MENU EXIT
RETURN
RETURNSEL. ENTER
[MARKER]
MARKER
16:9
4:3
BACK
CENTER
CROSS
COLOR
GPI MARKER1
GPI MARKER2
OFF
4:3
OFF
NORMAL
OFF
OFF
WHITE
95%(16:9)
95%(16:9)
Mark
LOCAL ENABLE
*
1
DISABLE
INPUT
FUNCTION
INPUT+FUNC.
Selects whether to enable or disable <INPUT SELECT> and <FUNCTION>
button operations when [REMOTE] is selected under [CONTROL].
[DISABLE] Disables <INPUT SELECT> and <FUNCTION> button
operations.
[INPUT] Enables <INPUT SELECT> button operations.
[FUNCTION] Enables <FUNCTION> button operations.
[INPUT+FUNC.] Enables <INPUT SELECT> and <FUNCTION> button
operations.
PROTOCOL VER.
*
2
V3.1
V4.0
Selects version of the TSL protocol.
RS-485 ID SETUP
0 to 126
(Factory default
setting: 0)
Sets the monitor ID number to use RS-485 communication.
RS-485 STX&ETX
OFF
ON
Select RS-485 interface command format (→page 63).
[OFF] STX and ETX need not be placed.
[ON] STX and ETX must be placed.
*
1
Only available when [REMOTE] is selected under [CONTROL].
*
2
The monitor supports version 3.1 and 4.0 of the TSL UMD PROTOCOL provided by Television System LTD.
HOURS METER
Submenu Setting Description
OPERATION
xxxxxxh
*
1
Displays the total number of hours it has been on.
LCD
xxxxxxh
*
1
Displays the number of hours that the backlight has been on.
*
1
“xxxxxx” indicates up to 262800 hours (about 30 years). [OVER] is indicated when the number of hours is 262800 or higher.