13
Indoor Model CS-BZ25XKE CS-BZ35XKE
Outdoor Model CU-BZ25XKE CU-BZ35XKE
Dimension Unit
Height
(I/D / O/D)
mm (inch) 290 (11-7/16) / 542 (21-11/32) 290 (11-7/16) / 542 (21-11/32)
Width
(I/D / O/D)
mm (inch) 779 (30-11/16) / 780 (30-23/32) 779 (30-11/16) / 780 (30-23/32)
Depth
(I/D / O/D)
mm (inch) 209 (8-1/4) / 289 (11-13/32) 209 (8-1/4) / 289 (11-13/32)
Weight Net (I/D / O/D) kg (lb) 8 (18) / 24 (53) 8 (18) / 25 (55)
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8) 6.35 (1/4) / 9.52 (3/8)
Standard Length m (ft) 5.0 (16.4) 5.0 (16.4)
Length Range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) 3 (9.8) ~ 15 (49.2)
I/D & O/D Height Different m (ft) 15.0 (49.2) 15.0 (49.2)
Additional Gas Amount g/m (oz/ft) 10 (0.1) 10 (0.1)
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16 16
Length mm 550 550
Indoor
Heat
Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 14 × 17 2 × 14 × 17
Size (W × H × L) mm 580 × 294 × 25.4 580 × 294 × 25.4
Outdoor
Heat
Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Corrugated Fin Corrugated Fin
Row × Stage × FPI 1 × 24 × 17 1 × 24:12 × 17
Size (W × H × L) mm 18.2 × 504 × 710 36.4 × 504:252 × 713:684
Air Filter
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord Nil Nil
Thermostat Electronic Control Electronic Control
Protection Device Electronic Control Electronic Control
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Indoor Operation
Range
Cooling
Maximum °C (°F) 32 (89.6) 23 (73.4) 32 (89.6) 23 (73.4)
Minimum °C (°F) 16 (60.8) 11 (51.8) 16 (60.8) 11 (51.8)
Heating
Maximum °C (°F) 30 (86.0) – 30 (86.0) –
Minimum °C (°F) 16 (60.8) – 16 (60.8) –
Outdoor Operation
Range
Cooling
Maximum °C (°F) 43 (109.4) 26 (78.8) 43 (109.4) 26 (78.8)
Minimum °C (°F) -10 (14.0) – -10 (14.0) –
Heating
Maximum °C (°F) 24 (75.2) 18 (64.4) 24 (75.2) 18 (64.4)
Minimum °C (°F) -15 (5.0) -16 (3.2) -15 (5.0) -16 (3.2)
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C.
5. Standby power consumption ≤ 2.0W (when switched OFF by remote control, except under self-protection control).
6. Specifications are subjected to change without prior notice for further improvement.
7. If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with
rated voltage 230V shall be used.
8. The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode.
9. SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating
season.