1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
Note:
Specification are subjected to change without prior notice for further improvement.
Item Unit Indoor unit Outdoor unit
Power Source
(Phase, Voltage, Cycle)
ø Single
V 240 - 220
Hz 50
Input power W 60 - 50 820 - 770 1.12k - 1.07k 1.21k - 1.15k 1.85k - 1.75k 1.92k - 1.84k
Starting Current A 15.0 21.0 A: 21.0 A: 21.0
B: 15.0
A: 21.0
B: 15.0
Running
Current
Cooling A 0.26 - 0.23 3.6 - 3.7 5.1 - 5.2 5.5 - 5.6 8.1 - 8.3 8.3 - 8.7
Power
Factor
Cooling % 95 - 95 92 - 94 92 - 93 95 - 96 96 - 96
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord Number
of core
Length m (ft)
Running Current
Protection Device 2 Stage Overload Protector