EasyManua.ls Logo

Panasonic CS-CZ25WKE - Page 96

Panasonic CS-CZ25WKE
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96
17.5.12 H33 (Unspecified Voltage between Indoor and Outdoor)
Malfunction Decision Conditions
The supply power is detected for its requirement by the indoor/outdoor transmission.
Malfunction Caused
Wrong models interconnected.
Wrong indoor unit and outdoor unit PCBs used.
Indoor unit or outdoor unit PCB defective.
Troubleshooting
When abnormality indication starts again
Is indoor unit and outdoor unit model numbers matched?
NO
Match the compatible model (follow specification)
Check indoor and outdoor units model number
Check the indoor and outdoor PCB part number and compare
if they matched part list.
Change for the specified indoor or outdoor unit PCB.
NO
YES
Replace the indoor and outdoor unit PCB.
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
Caution

Table of Contents

Other manuals for Panasonic CS-CZ25WKE

Related product manuals