76
To limit set temperature range for COOL & DRY, HEAT mode.
o Press “Set” button by using pointer.
o Press TEMP increment or decrement button to choose No. 3.
o Press Timer increment or decrement button to select desired temperature low limit of set temperature for
COOL & DRY mode.
o Press Timer Set button to confirm low limit selection.
o Press TEMP increment or decrement button to choose No. 4.
o Press Timer decrement or increment button to select desired temperature high limit of set temperature for
COOL & DRY mode.
o Press Timer Set button to confirm high limit selection.
Memorize new
Low2 range
Normal display mode
Press SW to enter customer zone &
Press SW’s to choose function 3
Press SW to confirm selection
Use SW or SW to change Low2 range
SET
i) Display latest set temp (Low2).
ii) After reset, Low2 = 16°C (by default)
Range = 16°C ~ [High2]
No code transmission
Memorize new
Normal display mode
Press SW to enter customer zone &
Press SW’s to choose function 4
Press SW to confirm selection
Use SW or SW to change High2 range
SET
i) Display latest set temp (High2).
ii) After reset, High2 = 30°C (by default)
Range = [Low2] ~ 30°C
No code transmission
High2 range