19. Technical Data
Technical data provided are based on the air conditioner running under free frequency.
19.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
19.1.1 CS-CZ25ZKE/CU-CZ25ZKE
Indoor (°C) Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 2699 2346 298 2536 2231 406 2500 2118 535
22.0 3012 1776 283 2793 1690 397 2454 1550 529
23
15.7 2563 2279 313 2372 2196 413 2114 2090 534
18.4 2775 1809 303 2527 1679 408 2269 1570 534
20
13.3 1830 1794 180 1742 1707 299 1656 1622 469
15.8 1844 1573 166 2278 1627 410 2032 1521 531
(Dry bulb value based on 46% humidity)
19.1.2 CS-CZ35ZKE/CU-CZ35ZKE
Indoor (°C) Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 3778 2878 521 3550 2737 710 3500 2598 935
22.0 4217 2178 494 3910 2074 694 3436 1901 925
23
15.7 3588 2797 546 3321 2694 722 2960 2565 933
18.4 3885 2220 530 3537 2059 713 3177 1926 933
20
13.3 2259 1977 235 2439 2296 522 2318 2219 820
15.8 2274 1661 222 3189 1996 717 2845 1866 928
(Dry bulb value based on 46% humidity)
TC - Total Cooling Capacity (W)
SHC - Sensible Heat Capacity (W)
IP - Input Power (W)