9.5.2. Ceiling type louver control
When power is on, at the same time, louver initialize 2 times.
During operation, stopping, thermostat is off condition, louver angle change as below table by manual setting or auto setting of
remote controller.
Remote controller setting Manual Auto
Operation mode Display
Set 1 Set 2 Set 3 Set 4 Piping temp (heating)
A B C
Normal 20° 35° 50° 70° 70° 20° - 70° Set 1
Heating Defrost 20°
Hot start 20°
Thermostat off 20°
Fan 20° 35° 50° 70° 20° - 70°
Cooling Normal 20° 35° 50° 70° 20° - 70°
(fan) Dew control 35°
Thermostat off 20° 35° 50° 70° 20° - 70°
Normal 35°
Dry Dew control 35°
Thermostat off 20° 35° 50° 70° 20° - 70°
Operation mode judge 20° 35° 50° 70° 20°
Stop mode 70°
30
CS-F24DTE5 CU-L24DBE5 / CS-F28DTE5 CU-L28DBE5