EasyManua.ls Logo

Panasonic CS-G123KE - Page 59

Panasonic CS-G123KE
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 64 –
MAC9509078C2
CS-G93KE
Technical Data
Piping Length Characteristic (Cooling) Cooling Characteristic
LL
LL
L Operation characteristics
CS-G123KE / CU-G123KE
3530
40
7
6
5
4
16
15
14
13
12
0.57
0.56
0.55
0.54
3.7
3.6
3.5
3.4
3.3
3.2
230V
GP: Gas Side
Piping Pressure (MPa) Temperature (°C)
O: Outlet Air
I: Current (A) Q: Cooling Capacity (kW)
I
OUTDOOR AIR TEMPERATURE (°C)
[Condition] Room temperature: 27/19°C
Cooling Operation: at High Fan
Piping length: 5m
Rated Fre
q
uenc
y
Operation
GP
Q
O
234567
7
6
5
4
15
14
13
12
11
0.58
0.57
0.56
0.55
0.54
0.53
3.6
3.5
3.4
3.3
3.2
3.1
230V
GP: Gas Side
Piping Pressure (MPa) Temperature (°C)
O: Outlet Air
I: Current (A) Q: Cooling Capacity (kW)
I
PIPING LENGTH (m)
[Condition] Room temperature: 27/19°C
Cooling Operation: 35/24°C
Piping length: at High Fan
Rated Fre
q
uenc
y
Operation
GP
Q
O
0–5
710
7
6
5
46
44
42
40
38
36
6.0
5.0
4.0
3.0
2.0
1.8
1.6
1.4
230V
GP: Gas Side
Piping Pressure (MPa) Temperature (°C)
O: Outlet Air
I: Current (A) Q: Heating Capacity (kW)
I
OUTDOOR AIR TEMPERATURE (°C)
[Condition] Room temperature: 20°C
Heating Operation: at High Fan
Piping length: 5m
Rated Fre
q
uenc
y
Operation
GP
Q
O
Piping Length Characteristic (Heating) Heating Characteristic
234567
8
7
6
5
44
43
42
41
40
39
2.0
1.9
1.8
1.7
4.9
4.8
4.7
4.6
4.5
4.4
230V
GP: Gas Side
Piping Pressure (MPa) Temperature (°C)
O: Outlet Air
I: Current (A) Q: Heating Capacity (kW)
I
PIPING LENGTH (m)
[Condition] Room temperature: 20°C
Heating Operation: 7/6°C
Piping length: at High Fan
Rated Fre
q
uenc
y
Operation
GP
Q
O
Untitled-2 6/21/00, 9:30 AM64

Related product manuals