MODEL
INDOOR CS-NE12LKE, CS-XE12LKE-5
OUTDOOR CU-NE12LKE
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.60 3.50 4.00
BTU/h
kcal/h 520 3010 3440
Running Current A 4.3
Input Power W 120 910 1.17k
Annual Consumption kWh 455
EER
W/W 5.00 3.85 3.42
kcal/hW 4.33 3.31 2.94
Power Factor % 92
Indoor Noise (H / L / QLo)
dB-A 42 / 29 / 26
Power Level dB 58 / - / -
Outdoor Noise (H / L)
dB-A 48 / -
Power Level dB 63 / -
Heating
Capacity
kW 0.60 4.00 6.60
BTU/h
kcal/h 520 3440 5680
Running Current A 4.5
Input Power W 115 960 1.85k
COP
W/W 5.22 4.17 3.57
kcal/hW 4.52 3.58 3.07
Power Factor % 93
Indoor Noise (H / L / QLo)
dB-A 42 / 33 / 30
Power Level dB 58 / - / -
Outdoor Noise (H / L)
dB-A 50 / -
Power Level dB 65 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP 4.78 / 1.64 / 2.91
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.86 / 1.74 / 2.22
Max Current (A) / Max Input Power (W) 8.4 / 1.85k
Starting Current (A) 4.5
Compressor
Type Hermetic Motor
Motor Type Brushless (4-poles)
Output Power W 750
Indoor Fan
Type Cross-flow Fan
Material ASG20K1
Motor Type Transistor (8-poles)
Input Power W 47.3
Output Power W 40
Speed
QLo
Cool/Fan rpm 760
Heat rpm 950
Lo
Cool/Fan rpm 850
Heat rpm 1010
Me
Cool/Fan rpm 1050
Heat rpm 1150
Hi
Cool/Fan rpm 1260
Heat rpm 1300
SHi
Cool/Fan rpm 1320
Heat rpm 1340

Table of Contents

Other manuals for Panasonic CS-NE9MKE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-NE9MKE and is the answer not in the manual?

Panasonic CS-NE9MKE Specifications

General IconGeneral
BrandPanasonic
ModelCS-NE9MKE
CategoryAir Conditioner
LanguageEnglish

Related product manuals