10
3. Specification
Model
Indoor CS-VZ9SKE
Outdoor CU-VZ9SKE
Performance Test Condition JIS, ErP
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity kW 0.60 2.50 3.00
Running Current A
—
2.05
—
Input Power W 140 430 660
Annual Consumption W
—
215k
—
EER W/W
—
5.81
—
ErP
Pdsign kW
—
2.5
—
SEER (W/W)
—
10.5
—
Annual Consumption kWh
—
83
—
Class
—
A+++
—
Power Factor %
—
91
—
Indoor Noise (H / L / QLo)
dB-A 44 / 27 / 18
Power Level dB 59 / - / -
Outdoor Noise (H / L)
dB-A 49
Power Level dB 64
Heating
Capacity kW 0.60 3.60 7.90
Running Current A
—
3.10
—
Input Power W 140 640 2.72k
COP W/W
—
5.63
—
ErP
warm/
ave./
cold
Pdsign kW 3.6
Tbivalent °C -10
SCOP (W/W) 6.2
Annual Consumption kWh 812
Class A+++
Power Factor %
—
91
—
Indoor Noise (H / L / QLo)
dB-A 44 / 26 / 18
Power Level dB 59 / - / -
Outdoor Noise (H / L)
dB-A 49
Power Level dB 64
Max Current (A) / Max Input Power (W) 15.0 / 3.45k
Starting Current (A) 3.1
Compressor
Type Hermetic Motor (Rotary)
Motor Type Brushless (6-poles)
Output Power W 900