18.2 Vertical Airflow Direction Louver
*Please replace the vertical airflow direction louver (for the upper side) in accordance with the following steps.
18.2.1 Steps to remove the vertical airflow direction louver (for the upper side)
1. Check that the product is plugged in.
2. Hold down the Eco Navi button on the remote
control for 5 seconds and wait until the
vertical airflow direction louver opens and
stops automatically.
Unplug after it stops.
※ Please operate with the power
unplugged from this point.
3. Take off the vertical airflow direction louver
(for the upper side)
① Pinch the tab of the fixed lock on the right
side.
② Slide it to the left side and remove the
right vane axis from the right stepping
motor axis.
③ Slowly take down the right side of the
vertical airflow direction louver (for the
upper side) to the point where it does not
contact the corner of the front grill. Slide
the vertical airflow direction louver (for
the upper side) to the right side and then
remove it from the main unit central axis
and the left stepping motor axis.
①
②
※ Pinch the tab and slide it to the left to remove.
※ Take it down to the position
where the right side of the
vertical airflow direction louver
(for the upper side) does not
contact the corner of the front
grill.
※ Slide it to the right to remove.
【Removal completed】
③