170
20. Service Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
20.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
Room Temperature: 27/19°C, Cooling Characteristic
Fan: High
Piping Length: 5.0 m
Freq: Rated Fc
20.1.1 CS-VZ9SKE CU-VZ9SKE
Outdoor Air Temperature (°C)
Current
(A)
Gas Side Piping
Pressure (MPa)
Outdoor Air Temperature (°C)
Outlet Air
(°C)
Outdoor Air Temperature (°C)
Capacity
(kW)
Outdoor Air Temperature (°C)
1.050
1.340
1.630
1.920
2.210
2.500
-10 -6 -2 2 6 10 14 18 22 26 30 34 38 43
1.150
1.170
1.190
1.210
1.230
1.250
Gas Side Piping
Pressure (Psi)
167.00
170.00
173.00
175.00
178.00
181.00
-10 -6 -2 2 6 10 14 18 22 26 30 34 38 43
15.000
15.400
15.800
16.200
16.600
17.000
-10 -6 -2 2 6 10 14 18 22 26 30 34 38 43
2.000
2.200
2.400
2.600
2.800
3.000
-10 -6 -2 2 6 10 14 18 22 26 30 34 38 43