63
14.2 Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
i. Manual Fan Speed
[Cooling, Dry]
Fan motor’s number of rotation is determined according to remote control setting.
Remote control O O O O
Tab Hi Me Me- Lo
[Heating]
Fan motor’s number of rotation is determined according to remote control setting.
Remote control O O O O
Tab Hi Me Me- Lo
ii. Auto Fan Speed
[Cooling, Dry]
According to room temperature and setting temperature, indoor fan speed is determined automatically.
The indoor fan will operate according to pattern below.
abc def gh
[1 pattern : 10 s]
ab
Higher
Fan
Speed
Medium
Lower
[Heating]
According to indoor pipe temperature, automatic heating fan speed is determined as follows.
RPM Increased
RPM Maintain
RPM Reduced
OFF
Indoor Pipe Temp.
35ºC
39ºC
16ºC
19ºC
B. Feedback control
Immediately after the fan motor started, feedback control is performed once every second.
During fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error
counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 – fan
motor error is detected.
Operation stops and cannot on back.