EasyManua.ls Logo

Panasonic CS-VZ9SKE - Page 64

Panasonic CS-VZ9SKE
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
14.2.1 CS-VZ9SKE
SSLo SLo Quiet Lo- Lo Me- Me Hi SHi
Fan speed: Manual 450 530 430 540 600 740 880 1010 1070
Cooling Range
Fan Speed: Auto
Normal
Outside air 35°C & Unstable

Other from the above

Initial airflow Area
Airflow stable/
Unstable
Area
Area

Dry Range
Normal Cool Dry
(Range )
(Range )
Initial airflow Area
Airflow stable/
Unstable
Area
Area
Heating range
Fan Speed: Manual 400 500 450 570 650 800 950 1110 ---
Fan Speed:
Auto
Initial airflow
/Unstable

Airflow
stable
Area
Area

Other than the above

Hot Dry
Blowing/Fan
Operation
Fan Speed: Manual --- --- 430 --- 600 740 880 1010 ---
Fan Speed: Auto
Individual +8/10°C HEAT 1110
Odor Cut Shift
Only for the COOL and DRY range
Below Me and Auto: No shifting Me and above: -90
Lock detection: When the rotation speed of 2550rpm and above or below 50rpm is detected for 10 consecutive seconds during the
feedback control, H19 is indicated (the TIMER indicator flashes) if normal rotation speed is not detected even after the retry is performed 7
times.
Refer to the attached list of “Indoor Unit Fan Operation Status” for the operations of the indoor unit fan while the thermostat id OFF.
O : Manual setting for remote controller (air discharge adjustable tap)
: Fan rotation speed
Area : Targeted area (air discharge changes based on human position)
: Rotation speed changes based on indoor pipe temperature
Attention: Other than above, there are tap and rotation limit and instructed rotation speed changes based on
capacity ranks and models

Table of Contents

Other manuals for Panasonic CS-VZ9SKE

Related product manuals