68
14.4.2 Horizontal Airflow
Automatic horizontal airflow direction can be set using remote control, the vane swings left and right within the angles
as stated below.
During Manual Setting
1 2 3 4 5 6 7
During Auto Setting Condition Middle Setting (default) Right Setting Left Setting
Heating Operation
C area 0°/0°
Auto
B area
Area Refer to the part of area air-conditioning
Neuro Unbalance 0° / 0° -25° / 25° 25° / -25°
Neuro balance
Powerful 0° / 0° -30° / 30° 30° / -30°
Normal 0±5° / 0±5° -25±5° / 25±5° 25±5° / -25±5°
A area -40° / -40° 40° / -40° -40° / 40°
Manual
Center, Non set
0° / 0° 10° / 10° -30° / -30°
-40° / 40° -40° / 0° 0° / -40° 40° / -40°
Left & right setting -40° / 50° -30° / 0° 0° / -30° 50° / -40°
Cooling Operation
Auto
Area Refer to the part of area air-conditioning
Powerful, beginning stage 0° / 0° -10° / 10° 10° / -10°
Normal, other than above 0±30° / 0±30° -15±15° / 15±15° 15±15° / -15±15°
Manual
Normal 0° / 0° 10° / 10° -20° / -20° -30° / 30° -30° / 0° 0° / -30° 30° / -30°
Dry Operation
Auto
Area Refer to the part of area air-conditioning
Other than above Similar to cooling automatic normal
Manual Similar to cooling manual normal
Blower operation Manual Similar to cooling manual normal
Demo mode 0±30° / 0±30°
Inside drying
0°/0°
Stop, stop de-ice
In weak heating operation
* B area: Left & right wind direction (twin independent configuration spec)
* The front position standard: Inward + outward - (Left blade/right blade)