14.7 Timer Control
There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
14.7.1 ON Timer Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than
the setting time.
This is to provide a comfortable environment when reaching the set ON time.
70 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
Indoor intake air
temperature (
o
C)
Outdoor air
temperature (
o
C)
30
30 35
Cooling/Dry
(
o
C)
10 min
15 min
5 min
25
Indoor intake air
temperature (
o
C)
Outdoor air
temperature (
o
C)
15
05
Heating
(
o
C)
30 min
20 min
40 min
5
14.7.2 OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
14.7.3 Sleep Timer
Sleep operation is performed according to the delay OFF time (0.5, 1, 2, 3, 5, 7, or 9 hour) and provide
comfortable environment by shifting set temperature.
This will automatically adjust the temperature to prevent your body from being cooled down or warmed up too
much.
Sleep timer
setting
All off
Maximum 9hr
Status 1 Status 2 Status 3 Status 4
Go to status 2 when
preset temperature is
reached or after 1hr
sleep timer has been
operated
Go to status 3 after
A hour
Go to status 4 after 7hr
sleep timer has been
operated or Time B is
reached
Heating Cooling, Dry
A 2hr 3hr
B *5am *4am
* According to remote control clock