14.15 Pre Heating Operation
Pre Heating operation learn and memorised everyday switch “ON” time of heating and pre heating to blow heat
wind as soon pressed the heating button.
Before setting, please make sure that the current time is correct.
If start operation in heating or pre-heating, the air conditioner could not blow hot air immediately because it is not
heat enough to blow hot air. (operation lamp will blink)
* Recommend: Clear the setting when not use the air conditioner in for a long time period.
The initial condition of the charging operation
Indoor unit learns every-day switch “ON” time
Memorizing every-day switch “ON”
time.
■ Setting is completed by pressing the charge
button on the remocon.
履
歴
■ Learning “ON” time based on the past record of
24hours (morning 0:00 – night 24:00).
When setting is completed,
the pre heating LED is lit.
7︓00
7︓30
8︓00
8︓30
Reverse counting
from the learnt time
Learnt time
band
Preliminary
operating time for
varied “ON” time.
Automatic pre-
heating
operation start
When “ON” in this time band,
Immediate heating and cooling
air discharge
Low Hz
Pre-heating
operation
Pre-heating
operation is
automatically
turned off, if not
switched on by
9:00.
Learning frequent operating
time band as “Frequently
operated time”.
9︓00
Time
No. of switching “ON”
Memorizing frequently
used time band.
History
Heating: The room temperature should be less than 18°C and the outdoor temperature should be less than 10°C and
previous operation is heating operation.
When relative temperature is high, pre-heating operation might be stopped for dew prevention.
Note:
* The air conditioner will learn and memorize the time zone that you used frequently and perform the pre-heating
operation.
* When it is in pre-heating operation, the operation lamp will not light up.
* Only when the previous operation is a heating, it will perform the pre-heating operation.
* If you do not press the heating button, it will perform the pre-heating operation for 60 min and finish it.