EasyManua.ls Logo

Panasonic CS-XE18WKUAW - Outdoor Unit

Panasonic CS-XE18WKUAW
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
8.2 Outdoor Unit
8.2.1 CU-XE9WKUA CU-XE12WKUA
Resistance of Compressor Windings
MODEL CU-XE9/12WKUA
CONNECTION 5RS102XTA21 ()
U-V 1.780
U-W 1.780
V-W 1.780
Note: Resistance at 68°F (20°C) of ambient temperature.
TO INDOOR UNIT
REACTOR
BLK
BLK
WHT
WHT
RED
NOISE FILTER
CIRCUIT
DATA
(RED)
AC-BLK
(BLK)
AC-WHT
(WHT)
FG1
(GRN)
FG2
(GRN)
1
1
3
5
3
W
10
14
16
IC19
V
U
CN–MTR2
ACN2 (BLU)
HT2 (BLU)
RY-HT2
BLU
BLU
BASE PAN
HEATER
3
1
(WHT)
CN–MTR1
(RED)
PFC
CIRCUIT
RECTIFICATION
CIRCUIT
RECTIFICATION
CIRCUIT
COMMUNICATION
CIRCUIT
SWITCHING
POWER
SUPPLY CIRCUIT
FUSE 1
(20A 250V)
FUSE 6
(20A 250V)
FUSE 8
T3.15A
L250V
FUSE 3
T3.15A L250V
FUSE 5
(20A 250V)
FAN
MOTOR
GRN
GRN
1L2L1 2 3
TERMINAL
BOARD
YELLOW
(YLW)
TRADEMARK
COMPRESSOR TERMINAL
THE PARENTHESIZED
LETTERS IS INDICATED
ON TERMINAL COVER
BLUE
(BLU)
RED
(RED)
CN–TH1
(WHT)
CN–TANK
(WHT)
CN–STM1
(WHT)
RED
BLU
YLW
U (RED)
V (BLU)
W (YLW)
U
V
W
1
4
1
3
1
6
P
N
Q1
OUTDOOR AIR TEMP. SENSOR (THERMISTOR)
PIPING TEMP. SENSOR (THERMISTOR)
COMPRESSOR TEMP. SENSOR (THERMISTOR)
CN–HOT
(WHT)
1
3
YLW
YLW
ELECTRO-MAGNETIC COIL
(4 -WAY VA LV E )
ELECTRO-MAGNETIC COIL
(EXPANSION VALVE)
REMARKS
BLU : BLUE
BLK : BLACK
WHT : WHITE
RED : RED
YLW : YELLOW
GRY : GRAY
GRN : GREEN
COMPRESSOR
MS
3~
ELECTRONIC CONTROLLER
MS
3~
RAT2
(GRY)
GRY
RAT1
(GRY)
GRY
M
SINGLE PHASE
POWER SUPPLY
GROUNDING TERMINAL
YLW/GRN

Table of Contents