18
Model
Indoor CS-XZ35XKEW-H
Outdoor CU-Z35XKE
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.85 3.50 4.20
BTU/h 2900 11900 14300
kcal/h 730 3010 3610
Running Current A - 3.90 -
Input Power W 200 850 1.16k
Annual Consumption kWh - 425 -
EER CLASS - A -
EER
W/W 4.25 4.12 3.62
BTU/hW 14.50 14.00 12.33
kcal/hW 3.65 3.54 3.11
ErP
Pdesign kW 3.5
SEER (W/W) 9.5
Annual Consumption kWh 129
Class A+++
Power Factor % - 95 -
Indoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
42 / 28 / 19 (Single)
44 / 30 / - (Multi)
Sound Power Level dB(A) 58 / - / -
Outdoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
48 / - / -
Sound Power Level dB(A) 63 / - / -
Heating
Capacity
kW 0.80 4.00 5.50
BTU/h 2730 13600 18800
kcal/h 690 3440 4730
Running Current A - 4.10 -
Input Power W 180 900 1.46k
COP CLASS - A -
COP
W/W 4.44 4.44 3.77
BTU/hW 15.17 15.11 12.88
kcal/hW 3.83 3.82 3.24
ErP
Pdesign kW 2.8
Tbivalent °C -10
SCOP (W/W) 5.2
Annual Consumption kWh 754
Class A+++
Power Factor % - 95 -
Indoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
43 / 33 / 19 (Single)
45 / 35 / - (Multi)
Sound Power Level dB(A) 59 / - / -
Outdoor Noise (H / L / QLo)
Sound Pressure Level
dB(A)
50 / - / -
Sound Power Level dB(A) 65 / - / -
LOW Temp: Capacity (kW) / I. Power (W) / COP 3.99 / 1.29k / 3.09
EXTR LOW Temp: Capacity (kW) / I. Power (W) / COP 3.20 / 1.26k / 2.54
Max Current (A) / Max Input Power (W) 6.4 / 1.46k
Starting Current (A) 4.10