Fan Type, Number of Set Sirocco fan-2 Prop. fan-1
Air Volume Control Three-Step and Auto mode
-
(Remote Control)
Motor Type 4-pole single phase induction
motor
6-pole single phase
induction motor
Input kW 0.20 0.11
Rated
Output
kW 0.150 0.05
Air-heat Exchanger Louvre-fin type Louvre-fin type
Refrigerant Control Capillary tube Capillary tube
Refrigerant Oil (Charged) L - MS32 (1.3)
Refrigerant (Charged) kg (oz) - R-22 2.5 (88)
Running
Adjustment
Control Switch Wired Remote Control -
Room Temperature Thermostat (Main Body) -
Safety Devices Internal protector for compressor, Internal thermostat for
F.M, Crankcase heater, Drain over-flow switch, High
pressure switch, Current Transformer
Noise Level (Sound Pressure) dB (A) Hi 45 Lo 43 Cooling 50 Heating 51
1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.)
and outdoor air temp. 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temp. 20° CD.B (68.0° FD.B.) and outdoor air temp. 7°C
D.B. (44.6°F D.B.), 6°C W.B. (42.8°F D.B.)
ELECTRICAL DATA (50Hz)
21