Outdoor unit Heat
pump
model
50Hz
CU-
A24BBP5
CU-
A28BBP5
CU-
A28BBP8
CU-
A34BBP5
CU-
A34BBP8
CU-
A43BBP8
CU-
A50BBP8
Cooling
only
model
50Hz
CU-
C24BBP5
CU-
C28BBP5
CU-
C28BBP8
CU-
C34BBP5
CU-
C34BBP8
CU-
C43BBP8
CU-
C50BBP8
Heat
exchanger
outlet
temperature
thermistor
(Th2)
Control
method
Th greater or equal to 30°C ---------- High speed
Th less than 30°C ---------- 5 speed step control
For control
protection
Fuse CUT A 6.3 6.3 6.3 6.3 6.3 6.3 6.3
(*) 1MPa=10.2kgf/cm
2
(*) Head Thermostat
14. COMPONENT SPECIFICATION
Compressor