17 10.81 9.62 3.04
10.32
9.46 3.26 9.88 9.28 3.49 9.25 8.88 3.71 8.52 8.52 3.90
29 19 11.33 8.27 3.26
10.92
8.19 3.49
10.39
8.01 3.71 9.88 7.80 3.93 9.25 7.50 4.12
22 12.26 6.26 3.63
11.86
6.28 3.82
11.33
6.23 4.04
10.81
6.17 4.23
10.18
6.01 4.46
17 10.73 9.55 3.04
10.32
9.39 3.26 9.79 9.21 3.49 9.18 8.82 3.71 8.46 8.46 3.90
32 19 11.24 8.21 3.26
10.83
8.12 3.49
10.32
7.94 3.71 9.79 7.74 3.93 9.18 7.44 4.12
22 12.17 6.20 3.63
11.76
6.23 3.82
11.24
6.18 4.04
10.73
6.12 4.23
10.11
5.97 4.46
Legend: BF Bypass Factor 0.20 SHC Sensible Heat Capacity TC Total Cooling Capacity / CAPACITY SELECTION NOTES / (1) The table above
is based on unit nominal evaporator airflow, / correction factor must therefore be applied for selections / away from this condition. /
COOLING CORRECTION FACTORS
EVAP. AIR FLOW m
3
/
min (l/s)
28 (467) 32 (533) 35 (583) 38 (633)
SHC Sensible Heat
Capacity
0.91 0.95 1.0 1.05
TC Total Cooling
Capacity
0.93 0.97 1.0 1.03
Model
CS-A43BD2P/CU-A43BBP8, CS-A43BD2P/CU-C43BBP8
COOLING PERFORMANCE
142