Noise Level (Sound Pressure) dB (A) Hi 45 Lo 43 Cooling 50 Heating 53
1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.)
and outdoor air temp. 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temp. 20° CD.B (68.0° FD.B.) and outdoor air temp. 7°C
D.B. (44.6°F D.B.), 6°C W.B. (42.8°F D.B.)
ELECTRICAL DATA (50Hz)
MODEL / ITEM
CS-A28BD2P/CU-A28BBP5
Condition by JIS B 8616
Volts V 220 230 240
Phase Single Single Single
Input Power kW Cool 2.69 2.69 2.69
Heat 2.61 2.61 2.61
Running Current A Cool 12.3 12.0 11.7
Heat 12.0 11.7 11.4
Starting Current A 50 52 54
Power Factor % Cool 99 97 96
Heat 99 97 95
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power
source
AC, 1~220V, 230V, 240V 50Hz
3.3 CS-A28BD2P / CU-A28BBP8