MODEL / ITEM
CS-A24BD2P/CU-A24BBP5
Condition by JIS B 8616
Volts V 220 230 240
Phase Single Single Single
Input Power kW Cool 2.59 2.59 2.59
Heat 2.50 2.50 2.50
Running Current A Cool 11.8 11.8 11.8
Heat 11.4 11.4 11.4
Starting Current A 49 51 52
Power Factor % Cool 99 95 91
Heat 99 95 91
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power
source
AC, 1~220V, 230V, 240V 50Hz
3.2 CS-A28BD2P / CU-A28BBP5
ITEM / MODEL
Indoor Unit Outdoor unit
Main Body CS-A28BD2P CU-A28BBP5
Cooling Capacity
kW 7.30
(BTU/h) (24,900)
Heating Capacity kW 7.75
(BTU/h) (26,400)
Refrigerant Charge-less m 30
Standard Air Volume for High
Medium and Low Speed
m
3
/min
Hi 20 Hi 43
cfm Hi 706 1518
External Static Pressure mmAq Hi 10 Me 7 Lo 5 -
Pa Hi 98 Me 69 Lo 49
22