Noise Level (Sound Pressure) dB (A) Hi 47 Lo 45 56
1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.)
and outdoor air temp. 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temp. 20° CD.B(68.0° FD.B.) and outdoor air temp. 7°C
D.B. (44.6°F D.B.), 6°C W.B. (42.8°F D.B.)
ELECTRICAL DATA (50Hz)
MODEL / ITEM
CS-A34BD2P/CU-A34BBP5
Condition by JIS B 8616
Volts V 220 230 240
Phase Single Single Single
Input Power kW Cool 3.95 3.95 3.95
Heat 3.55 3.55 3.55
Running Current A Cool 19.0 19.1 19.2
Heat 17.9 18.0 18.1
Starting Current A 94 99 103
Power Factor % Cool 94 90 86
Heat 90 86 82
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power
source
AC, 1~220V, 230V, 240V 50Hz
3.5 CS-A34BD2P / CU-A34BBP8