and outdoor air temp. 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.) / / / / / /
ELECTRICAL DATA (50Hz)
MODEL / ITEM
CS-A28BD2P/CU-C28BBP5
Condition by JIS B 8616
Volts V 220 230 240
Phase Single Single Single
Input Power kW Cool 2.69 2.69 2.69
Running Current A Cool 12.3 12.0 11.7
Starting Current A 50 52 54
Power Factor % Cool 99 97 96
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power
source
AC, 1~220V, 230V, 240V 50Hz
4.3 CS-A28BD2P / CU-C28BBP8
ITEM / MODEL
Indoor Unit Outdoor unit
Main Body CS-A28BD2P CU-C28BBP8
Cooling Capacity kW 7.30
(BTU/h) (24,900)
Refrigerant Charge-less m 30
Standard Air Volume for High
m
3
/min
Hi 20 Hi 43
Medium and Low Speed cfm Hi 706 1518
External Static Pressure mmAq Hi 10 Me 7 Lo 5 -
Pa Hi 98 Me 69 Lo 49
Air Inlet Backward Suction Rear sided Suction
Air Outlet Front blow-out Front blow-out
Outside Dimension (H x W x D) mm 290 x (1000 + 10) x 500 900 x 900 x 320