MODEL / ITEM
CS-A28BD2P, CU-A28BBP8
Condition by JIS B 8616
Volts V 380 400 415
Phase 3N 3N 3N
Input Power kW Cool 2.69 2.69 2.69
Heat 2.61 2.61 2.61
Running Current A Cool 4.5 4.45 4.4
Heat 4.3 4.25 4.2
Starting Current A 28 29 30
Power Factor % Cool 91 87 85
Heat 92 89 86
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power
source
AC, 3N~380V, 400V, 415V 50Hz
3.4 CS-A34BD2P / CU-A34BBP5
ITEM / MODEL
Indoor Unit Outdoor unit
Main Body CS-A34BD2P CU-A34BBP5
Cooling Capacity
kW 10.45
(BTU/h) (35,600)
Heating Capacity kW 11.20
(BTU/h) (38,200)
Refrigerant Charge-less m 30
Standard Air Volume for High
Medium and Low Speed
m
3
/min
Hi 35 Hi 70
cfm Hi 1236 2471
External Static Pressure mmAq Hi 10 Me 7 Lo 5 -
Pa Hi 98 Me 69 Lo 49