12.2.4 Connect the Cable to the Indoor Unit
1. The inside and outside connection cable can
be connected without removing the front grille.
2. Unscrew the conduit cover and fix the conduit
connector to conduit cover with lock nut, then
secure it against chassis.
3. Connecting wire between indoor unit and
outdoor unit should be UL listed or CSA
approved 4 conductor wires minimum AWG16
in accordance with local electric codes.
o Ensure the colour of wires of outdoor unit
and terminal number are the same as the
indoor's repectively.
o Earth lead wire shall be Yellow/Green
(Y/G) in colour and shall be longer than
other lead wires as shown in the figure for
electrical safety in case of the slipping.
Rear view for left piping installation
Drain cap
Drain hose
Adjust the piping slightly downwards.
Drain hose
Connection
cable
How to pull the piping and drain hose out, in case of em bedded piping.
How to insert the connection cable and drain hose
inthecaseofleftpiping.
Cable
4
5
°
Drain
hose
Piping
(For right piping, follow the same procedure)
Sleeve for piping hole
Drain hose
Piping
Connection
cable
More than 45
9
/
32
"
(1150 mm)
Replace the drain hose
Indoor unit
drain hose
3/4" (20 mm ) nominal PVC pipe
- Install incline downward more than
- Apply PVC glue at the join.
Drain hose adapter
9
Close join by V inyl Tape ( )
Join indoor drain hose to 3/4" (20 mm) nom inal PVC pipe size
by using drain hose adapter
9
when necessary.
Drain hose adapter
9
usage
Remarks :
Make sure indoo r unit drain hose & 3/4" (20 mm ) nom inal PV C pipe
are fully inserted to drain hose adapter
9
.
2
27
/
32
" (72 mm)
M
o
r
e
t
h
a
n
1
8
1
/
2
"
(
4
7
0
m
m
)
M
o
r
e
t
h
a
n
4
5
9
/
3
2
"
(
1
1
5
0
m
m
)
More than 27
9
/
16
"
(700 mm)
PVC tube
for dra in
hose
Indoor unit
Piping
Cable
Apply putty or
caulking material
to seal the wall
opening.
Connection cable
Piping
PVC tube (VP-65) for piping
and conne ction cable
PVC tube for drain hose (VP-30)PVC tube for drain
hose (VP-20)
Drain hose
from main un it
Terminals on the indoor unit 1 2 3
Colour of wires (Connecting wire)
Terminals on the outdoor unit 1 2 3
WARNING
This equipment must be properly earthed.
123
Earth Wire
longer than
others AC
wires for
safety
reason
Term i n al
Board
Holder
Indoor and
outdoor
connection
cable
Chassis
Conduit
Connector
Conduit
Cover
Lock Nut
Rear Side of Indoor Unit