EasyManua.ls Logo

Panasonic CU-RE9JKE-1 - Product Specification

Panasonic CU-RE9JKE-1
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
Indoor Unit
Outdoor Unit
Model
CS-RE9JKE-1
CU-RE9JKE-1
CS-RE12JKE-1
CU-RE12JKE-1
CS-RE15JKE-1
CU-RE15JKE-1
COOL HEAT COOL HEAT COOL HEAT
Single, 230V, 50Hz Single, 230V, 50Hz Single, 230V, 50Hz
Power/Current
[kW] 0.700 0.820 1.010 1.120 1.260 1.385
[A] 3.30 3.70 4.70 5.20 6.00 6.30
Refrigerant
[k
g
]
R410A
0.850
R410A
0.970
R410A
1.000
Cooling Capacity
[kW] 2.500 3.500 4.200
Heating Capacity
[kW] 3.300 4.250 5.000
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
42 42 42 42 46 46
Conditions
1m Distance
Max. cooling/
heating
operation
47 48 48 50 50 51
Sound power
level
[dB(A)]
58 58 58 58 62 62
63 64 64 66 66 67
Air Circulation
[m
3
/min.] 12.5 12.5 12.6 13.3 14.0 15.6
kg
Product Weight
[k
g
]
9.0 9.0 9.0
24 28 29
Dimensions (L x W x H)
[mm]
848 × 204 × 290
780 × 289 × 540
PRODUCT SPECIFICATION
Test conditions
1.
Temperature (°C)
Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING 27 19 35 24
HEATING 20 12 7 6
2. Standard piping length: 7.5 m (Includes Indoor Unit piping length).
F567311 Book.indb 62F567311 Book.indb 62 2010-02-05 3:32:55.MD2010-02-05 3:32:55.MD