20.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 20°C DryBulb/-°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230/240V
20.2.1 CS-RZ25TKR CU-RZ25TKR
Outdoor
Temperature (°C)
Indoor Discharge
Air Temperature
(°C)
-15 28.47
-7 29.06
2 30.02
7 32.79
24 40.82
Outdoor
Temperature (°C)
Current (A)
230V 240V
-15 2.97 2.87
-7 3.08 2.98
2 3.27 3.17
7 3.50 3.40
24 4.08 3.98
Outdoor
Temperature (°C)
Gas Side Piping
Pressure
(MPa) (Psi)
-15 1.926 279.000
-7 1.935 281.000
2 2.015 292.000
7 2.216 321.000
24 2.917 423.000