What causes Indoor/Outdoor abnormal communication in a Panasonic Air Conditioner?
- DDaniel JamesAug 5, 2025
Abnormal communication between the indoor and outdoor units can be caused by the connecting cable or issues with the indoor/outdoor PCB.
What causes Indoor/Outdoor abnormal communication in a Panasonic Air Conditioner?
Abnormal communication between the indoor and outdoor units can be caused by the connecting cable or issues with the indoor/outdoor PCB.
What causes Indoor fan motor mechanism lock in Panasonic Air Conditioner?
A locked indoor fan motor mechanism can be caused by the indoor PCB or the fan motor itself.
Outdoor unit weight | 26000 g |
---|---|
Outdoor units quantity | 1 |
Outdoor unit noise level | 66 dB |
Cooling airflow (outdoor unit) | 1956 m³/h |
Heating airflow (outdoor unit) | 1896 m³/h |
Outdoor unit dimensions (WxDxH) | 780 x 289 x 540 mm |
Type | Air conditioner outdoor unit |
Ionizer | - |
Air filter | Yes |
Compressor type | Rotary |
Built-in display | No |
Hose length (max) | 15 m |
Refrigerating medium | R410A |
Cooling capacity (max) | - BTU/h |
Dehumidifying capacity | 2 l/h |
Air conditioner functions | Cooling, Heating |
Refrigerating medium weight | 860 g |
Cooling capacity in watts (max) | 3900 W |
Cooling capacity in watts (min) | 900 W |
Heating capacity in watts (max) | 4900 W |
Cooling energy efficiency (EER, W/W) | 3.47 |
Heating energy efficiency (COP, W/W) | 3.79 |
Seasonal efficiency rating (cooling) (SEER) | 5.6 |
Seasonal efficiency rating (heating) (SCOP) (Average heating season) | 3.4 |
Indoor unit type | Wall-mountable |
Indoor units quantity | 0 |
Power requirements | AC 230 V |
Power consumption (cooling) (max) | 1200 W |
Power consumption (cooling) (min) | 170 W |
Power consumption (heating) (max) | 1460 W |
Power consumption (heating) (min) | 150 W |
Annual energy consumption (cooling) | 219 kWh |
Annual energy consumption (heating) (Average heating season) | 1318 kWh |
Steps to insert AAA or R03 batteries into the remote control.
Procedure to set the timer on the remote control.
How to operate the unit: select mode, start/stop, and set temperature.
Covers warnings, cautions, prohibited, and compulsory actions for safe operation.
Safety instructions for indoor/outdoor units, remote control, and power supply.
Instructions for turning on/off and setting the temperature via remote control.
How to select fan speeds and activate the quiet environment setting.
Guidance on adjusting horizontal and vertical airflow directions.
Using the unit's button for operation when remote control is unavailable.
Procedures for cleaning the indoor unit's front panel and body.
Steps for cleaning and maintaining the air filters.
Checks for seasonal inspection after extended non-use and for extended non-use.
Common symptoms that do not indicate a unit malfunction.
Steps to check before calling for professional servicing.
Procedure to retrieve error codes using the remote control.
Specifications for power, current, refrigerant, and cooling/heating capacity.
Details on noise levels, sound power, and air circulation rates.
Product weight, dimensions, standby power, and piping length.
Guidance on proper disposal of electrical/electronic products and batteries.
Information for business users on discarding electrical and electronic equipment.
Information on disposal methods for countries outside the European Union.