EasyManua.ls Logo

Panasonic CW-XC100AU - AIR CONDITIONER INSTALLATION; Installation Components and Tools

Panasonic CW-XC100AU
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model CW-XC100AU & CW-
XC120AU
Connection CWA951047
Blue - Yellow 21.0
Yellow - Brown 5.2
Brown - Orange 6.7
Red - Yellow 28.0
Capacitor CWA312046
(10 F, 230VAC)
5.3. Resistance of Compressor windings and the rated Capacitor.
Model CW-XC100AU CW-XC120AU
Connection 2P14S126B1Q 2P16S126B1M
C-R 0.777 0.666
C-S 2.252 2.163
Capacitor CWA31410
(40 F, 250VAC)
CWA31411
(45 F, 250VAC)
Note: Resistance at 68°F of Ambient Temperature.
6. Air Conditioner Performance Evaluation
Suction & Discharge
Air Temperature
Difference
Current Determination Remedy
-8°C and over (14.4°F) -As specified. -Nothing wrong. -None.
-8°C and over (14.4°F) -Higher than specified. -Nothing wrong, outdoor
temperature is too high, heat
radiation is not efficient.
-Improve heat radiation.
-Under 8°C (14.4°F) -Higher than specified. -Something is preventing heat
radiation.
-Excessive amount of
refrigerant.
-Improve heat radiation.
-Under 8°C (14.4°F) -Lower than specified. -Leakage of refrigerant or
refrigerant system is blocked.
-Locate and repair leak.
-Flush refrigeration cycle.
-Under 8°C (14.4°F) -Higher than specified by 50%. -Compressor defect. -Replace the compressor.
Note: Room air humidity is relatively higher, the temperature difference will be smaller.
7. Troubleshooting Guide
Warning: Disconnect unit from electrical power supply before making any electrical checks.