PRODUCT SPECIFICATIONS
Model CW-XC100VK CW-XC120VK
COOLING CAPACITY Btu/h 10,000 11,500
ELECTRICAL RATING Phase Single +
Frequency (Hz) 60 +
Voltage (V) 115 +
Current (Amps) 8.7 9.8
Input (W) 980 1120
EER (Btu/W.h) 10.2 +
MOISTURE REMOVAL (Pints/h) 2.5 3.0
ROOM AIR CIRCULATION (Cf/min) 320 330
DIMENSIONS Height cm (inches) 37.5 (14-
25
/
32
˝) +
Width cm (inches) 56 (22-
1
/
16
˝) +
Depth cm (inches) 60.6 (23-
27
/
32
˝) +
NET WEIGHT kg (lb) 35 (77) +
GROSS WEIGHT kg (lb) 39 (86) +
NOISE LEVEL Indoor (Hi/Lo) dB (A) 50/46 51/47
Outdoor (Hi/Lo) dB (A) 57/54 58/55
JET MODE OPERATION
SETTING THE OFF TIMER
When the air conditioner in operation:
Press the TIMER button.
The SET/CANCEL indicator light will
blink awaiting for setting.
Press the TEMP/TIMER
▲ or ▼ button
until the preferred hour of operation is
reached.
Press the SET/CANCEL button to
complete the setting. At this time, the
SET/CANCEL indicator light is steady
instead of blinking.
NOTE
The hour reading will change back to the
set temperature reading after 10
seconds. (You can also revert to
temperature setting immediately by
pressing the TEMP/TIMER
▲ or ▼
buttons again.)
CHECK TIMER SETTING DURING OFF TIMER
Press the TIMER button to check the
remaining programmed timer setting.
The figure will be displayed for 10
seconds then will automatically switch
back to temperature setting.
NOTE
The timer figure will change according
to the time remaining (if you set it to turn
off 3 hours from now, the timer will show
“2” at an hour later).
CANCEL TIMER SETTING DURING OFF TIMER
Press the SET/CANCEL button to cancel
the timer setting. The SET/CANCEL
indicator light will turn off. However the
temperature remains displayed.
SETTING THE ON TIMER
When the air conditioner is OFF:
Press the TIMER button. The TIMER
indicator light will blink to await for setting.
Press the TEMP/TIMER
▲ or ▼
button
until the desired hour for operation is
reached. Press the SET/CANCEL button
to complete the setting. At this time, the
TIMER indicator light is steady instead of
blinking.
The display will show the remaining hour
to the start of the operation (if you set to
turn on 3 hours from now, the timer will
show “2” at an hour later).
When set time is reached, the air
conditioner starts the operation under the
previous setting mode and the TIMER
indicator will light off. Now, the previous
set mode and the fan speed will light up.
Simultaneously, the display will show the
setting temperature.
CHECK TEMPERATURE/MODE/FAN SPEED
SETTING DURING ON TIMER
Press the TIMER button. The TIMER
indicator light will blink and the previous
temperature setting will be shown.
Simultaneously, MODE and FAN SPEED
indicator will light up. This indication will
last for 5 seconds, and then the display
will show the remaining time. MODE and
FAN SPEED indicator light will turn off.
At this time, the TIMER indicator light is
steady instead of blinking.
CHANGE TEMPERATURE/MODE/FAN SPEED
SETTING DURING ON TIMER
Press the SET/CANCEL button to
cancel the timer setting.
Press the OPERATION. Set the desired
temperature, mode and the fan speed.
Then press OPERATION button to stop
operation.
Start the TIMER setting again by
repeating the step from the “Setting the
on timer” procedures).
CANCEL TIMER SETTING DURING ON TIMER
Press the SET/CANCEL button to cancel the
timer setting. The SET/CANCEL indicator
light will turn off. To operate the air
conditioner before reaching the set timer:
• Press the SET/CANCEL to cancel the
timer.
• Press the OPERATION button to turn on
the unit.
JET
MODE
TIMER
TEMP/TIMER
SET
SET/
CANCEL
TIMER
SET
SET/
CANCEL
TIMER