8-11
8
Use [Emergency Operation] in the following situations when there is an urgent need.
When the remote controlās batteries have failed.
When the remote control is broken.
When the remote control is lost.
*1
Figures: CZ-RWSU2, CZ-WRSY2, CZ-RWST2 and CZ-RWST3 are of receivers (inside indoor unit),
CZ-RWSL2 is of the operation panel (inside indoor unit) and Indoor Unit (CZ-RWSK2) is of its front panel.
CZ-RWSU2 / CZ-RWST2 / CZ-RWSY2 / Indoor Unit (CZ-RWSK2) / CZ-RWST3
Start : press [Emergency Operation] of the receiver.
If the indoor temperature is 24 °C or greater when the unit starts running, it will act as a cooling mode.
If the indoor temperature is less than 24 °C when the unit starts running, it will act as a heating mode.
Stop : press [Emergency Operation]
of the receiver again.
The Test Run/On and Test/On switches are for use when the unit is installed and test run. It is not for normal use.
If the [Normal/Stop ALL] switch is on Stop ALL, the unit cannot receive signals from the remote control.
CZ-RWSC2 / CZ-RWSL2
1. Press [Emergency Operation] of the receiver.
If the indoor temperature is 24 °C or greater when the unit starts running, it will act as a cooling mode.
If the indoor temperature is less than 24 °C when the unit starts running, it will act as a heating mode.
2. If you press
, the wind direction automatically oscillates up and down.
Stop : press [Emergency Operation]
of the receiver again.
21
CZ-RWSL2 CZ-RWSC2
The Test Run/On and Test/On switches are for use when the unit is installed and test run. It is not for normal use.
If the [Normal/Stop ALL] switch is on Stop ALL, the unit cannot receive signals from the remote control.
NOTE
NOTE
8-11. Emergency Operation
Indoor Unit (CZ-RWSK2)CZ-RWST2
Start/Stop
CZ-RWSY2
Start/Stop
CZ-RWSU2
2
1
Start/Stop
Start/Stop
CZ-RWST3
Start/Stop