179
DP-8032/8025
2008Ver. 1.2
2. Output Check
Press the “START” key to start and press the “STOP” key to reset.
021 Home Position Sensor Home position is
detected.
1 (270)
ADF/Platen Cover Open Sensor ADF/Platen Cover is
open.
1 (1903)
ADF/Platen Cover Angle
Sensor
ADF/Platen Cover is
open more than 30°
angle.
1
Fuser Lamp Disconnect
Detection Sensor
No Lighting 1
---
+24V Line Error Detecting
Signal
+24V Line is ON. 1
022-
029
Not Used
030 ADF B1 Sensor Original is detected. 1 (1045) Fig.18/33 C6
ADF B2 Sensor Original is detected. 1 (1045) Fig.17 C7
Fig.32 G4
ADF Paper Exit Detection
Sensor
Original is detected. 1 (1045) Fig.17 C8
ADF Inverting Cover Open
Detection Sensor
Cover is open. 1 (1045) Fig.17 G2
Fig.32 D3
ADF Cover Open Detection
Sensor
Cover is open. 1 (1045) Fig.16/33 E1
ADF Detection Sensor 1 See Remarks. * iADF
Signal 1 = 1
Signal 2 = 1
ADF
Signal 1 = 1
Signal 2 = 0
A different signal
pattern, indicates that
the unit is not
connected.
ADF Detection Sensor 2 See Remarks. *
031 ADF Original Sensor Original is detected. 1 (1045) Fig.17/32 G2
ADF Original Width Sensor Original is detected. 1 (1981)
ADF Original Width Sensor Original is detected. 1
ADF Original Length Sensor 2 Original is detected. 1 (1045) Fig.16/31 K2
ADF Original Length Sensor 1 Original is detected. 1
032-
039
Not Used
F4 Mode (Output Check)
No. Item Function
Remark
(Ref.No.)
040 Total Counter When SPC PCB CN715-8 signal level changes to
0V from +24V, count up the Total Counter.
---
F4 Mode (Input Check)
No. Function Condition
Message
Display
Remarks
(Ref.No.)
76543210