5.1.5. F6 Mode: Adjust Parameters (For Copier)
Set the machine to Service Mode and press “6” key on the Keypad.
Press the “START” key.
Select the desired code number on the Touch Panel display.
If you wish to select another code number, scroll the menu with the arrow buttons.
Select the desired function on the Touch Panel display and touch the “OK” button.
When the “C (CLEAR)” key is touched, the selected code input will not be accepted.
Press “FUNCTION” and “C (CLEAR)” keys simultaneously to exit the service mode.
Reboot the machine after setting the parameter(s) to activate the setting(s).
F6 Mode
No. Item Remarks
Setting
Range
00 Adj 100% Side-Side Read Adjustment of ratio for vertical position when scan
is made.
-9 ~ +9
0.1 %
01 Adj 100% Lead-Tail Read Adjustment of ratio for parallel position when scan
is made.
-9 ~ +9
0.1 %
02 100% Selection Adjustment from 99.1% to 100.9% -9 ~ +9
0.1 %
03 Original Registration Adjustment of platen original registration detection
timing.
-30 ~ +30
0.2 mm
04 Printer Registration Delay time is adjusted from registration roller clutch
ON.
-50 ~ +50
0.5 mm
05 Main Motor Speed Adjustment of Main Motor speed. -10 ~ +10
0.1 %
06 Polygon Motor Speed Adjustment Polygon Motor speed. -5 ~ +5
0.1 %
07 Registration Void Registration void should be adjusted. 0 ~ +99
0.5 mm
08 Trail Edge Read Timing Adjustment of trail edge void. -9 ~ 0
0.5 mm
09 Trail Edge Print Timing Adjustment of trail edge void. -9 ~ +15
0.5 mm
10 Side Adjust (Bypass) Adjustment of LSU side-side (Sheet Bypass). -8 ~ +7
0.5 mm
11 Side Adjust (Tray 1) Adjustment of LSU side-side (1st Tray). -8 ~ +7
0.5 mm
12 Side Adjust (Tray 2) Adjustment of LSU side-side (2nd Tray). -8 ~ +7
0.5 mm
13 Side Adjust (Tray 3) Adjustment of LSU side-side (3rd Tray). -8 ~ +7
0.5mm
14 Side Adjust (Tray 4) Adjustment of LSU side-side (4th Tray) -8 ~ +7
0.5 mm
15 Not Used
16 Side Adjust (ADU) Adjustment of LSU side-side (ADU). -8 ~ +7
0.5 mm