190
DP-8032/8025
2008Ver.1.2
17 Charge Roller Voltage Charge voltage compensation adjustment. -76 ~ +76
2.60 V
18 Standard Laser Power Laser power compensation adjustment. -29 ~ +25
19 Std Bias DC Voltage Adjustment of bias standard voltage. -76 ~ 76
2.60 V
20 Not Used
21 TDC Gain Voltage Adjustment of toner density sensor gain voltage. -86 ~ +40
0.033 V
22-24 Not Used
25 Bias Duty Ratio
(Factory use only)
Bias duty ratio adjustment -5 ~ +5
0.80 %
26 TDC Judgment Level Adjustment of toner supply starting judgement
voltage level.
-26 ~ +26
19.5 mV
27 Bias Frequency
(Factory use only)
AC Bias frequency adjustment -5 ~ +3
28 QUANTUM White Density Adjustment of standard white density level. -99 ~ +99
29 QUANTUM Black Density Adjustment of standard black density level. -99 ~ +99
30 Light Halftone Adj. Halftone duty ratio adjustment -127 ~ +127
31 Fuser Temperature Adjustment of fuser temperature. -15 ~ +15
0.833 °C
32 Fuser Edge Temperature Temperature compensation for edges -15 ~ +15
0.833 °C
33 TDC Max. Read Only Set by Digital QUANTUM (QUARC) control -99 ~ +99
(Read only)
34 TDC Min. Read Only Set by Digital QUANTUM (QUARC) control -99 ~ +99
(Read only)
35 TDC Avg. Read Only Set by Digital QUANTUM (QUARC) control -99 ~ +99
(Read only)
36 Paper Loop (Tray 1) Individual Fine Adjustment for Tray 1 -99 ~ +99
0.176 mm
37 Not Used
38 ID Standard Voltage Adjustment of judgement standard voltage. -35 ~ +35
39 LSU Unit PWM Adjust Adjustment of PWM value of LSU. -32 ~ +32
40 Transfer Current Side 1 Adjustment of Transfer Current. -16 ~ +15
0.6 µA
41 Paper Loop (Bypass) Individual Fine Adjustment for Sheet Bypass -99 ~ +99
42 Paper Loop (Tray 2) Individual Fine Adjustment for Tray 2 -99 ~ +99
0.176 mm
43 Paper Loop (2-Sided) Adjustment for the length of the loop formed before
the copier timing roller.
-99 ~ +99
0.176 mm
44 FAX Laser Duty Adj Printer Density Adjustment for FAX.
(-) : Darker.
(+) : Lighter.
-99 ~ +99
45 Not Used
46 PRINTER Laser Duty Adj Printer Density Adjustment for Printer.
(-) : Darker.
(+) : Lighter.
-99 ~ +99
47 Transfer Current Side 2 Adjustment of Transfer Current. -16 ~ +15
0.6 µA
F6 Mode
No. Item Remarks
Setting
Range