533
DP-C405/C305/C265
FEB 2008Ver. 1.1
328 ADF 100% Image 1-Sided Identical vertical (side-to-side) size ratio
adjustment.
-9 ~ +9
0.1%
329 ADF 100% Image 2-Sided
Identical horizontal (top-to-bottom) size ratio
adjustment.
-9 ~ +9
0.1%
330 FB Lead Void (NWS) Lead edge void for Network Scanner (FB)
adjustment.
0 ~ +9
0.5 mm
331 FB Side Void (NWS) Side edge void for Network Scanner (FB)
adjustment.
0 ~ +9
0.5 mm
332 FB Trail Void (NWS) Trail edge void for Network Scanner (FB)
adjustment.
0 ~ +9
0.5 mm
333-
334
Not Used
335 ADF Lead Void (NWS) Lead edge void for Network Scanner (ADF)
adjustment.
0 ~ +9
0.5 mm
336 ADF Side Void (NWS) Side edge void for Network Scanner (ADF)
adjustment.
0 ~ +9
0.5 mm
337 ADF Trail Void (NWS) Trail edge void for Network Scanner (ADF)
adjustment.
0 ~ +9
0.5 mm
338-
399
Not Used
400 AC Charge Freq.Adj. Full
(Factory use only)
-77 ~ +127
401 AC Charge Freq.Adj. Half -107 ~ +127
402 AC Charge Freq.Adj. B/W -58 ~ +127
403-
404
Not Used
405 AC Charge Adj. Y Full
(Factory use only)
-127 ~ +92
3.79 µA/step
406 AC Charge Adj. M Full -127 ~ +92
3.79 µA/step
407 AC Charge Adj. C Full -127 ~ +92
3.79 µA/step
408 AC Charge Adj. BK Full -127 ~ +92
3.79 µA/step
409 Not Used
F6 Mode