24
English
Problem Possible cause Action
The appliance stops during
operation.
The appliance is pressed against
skin too hard.
Contact to skin with gentle force.
Not charged fully. Fully charge the appliance.
Cannot remove
hair.
When epilating
The appliance is used on long hair.
Use on hair approximately 2 to 3 mm
long.
The epilation head surface is not
contacting to skin closely.
The appliance is not moved
against the ow of hair.
Make the epilation head surface
contact to skin closely and move.
Move the appliance against the ow
of hair.
(Refer to page 17.)
The hair
becomes
stubble.
The appliance is moved too fast.
Move it slowly. (approximately
3~5 cm/sec)
(Refer to page 17.)
The appliance
is not removing
the hair as well
as before.
Hair dust has accumulated. Clean the hair dust.
The skin protector or discs are
deformed, cracked, or damaged.
Request repair at an authorized
service center.
Sensitive area
cap comes off
during
operation.
The appliance is pressed against
skin too hard.
Contact to skin with gentle force.
The appliance is not applied at a
90° angle to your skin.
Apply at a 90° angle to your skin.
(Refer to page 17.)
The appliance
is not cutting as
well as before.
When shaving
Hair dust has accumulated. Clean the hair dust.
The blade is deformed.
Replace the blade.
Guidelines for replacement:
Outer foil: Approximately 1 year
Inner blade: Approximately 2 years
The blade is worn out.
ES-EL9A USA v7.indb 24 2019/1/15 下午6:18