Multiplic
ation
Timing chart
Incrementation Decrementation
Multiply
by 4
Count operation of individual input
Multiplic
ation
Timing chart
Incrementation Decrementation
Multiply
by 1
Multiply
by 2
Count operation of direction detection input
Multiplic
ation
Timing chart
Incrementation Decrementation
Multiply
by 1
Multiply
by 2
Input time constant
Input time constants can be set for input signals (phases A, B, and Z) and control signals.
Input signal name Settings
Input A signal, input B
signal
(The same time constant
for both signals)
No input time constant / 0.1 µs (2 MHz) / 0.2 µs (1 MHz) / 0.5 µs (500 kHz) / 1.0 µs
(250 kHz) / 2.0 µs (100 kHz) / 10.0 µs (10 kHz)
Input Z signal
No input time constant / 0.1 µs (2 MHz) / 0.2 µs (1 MHz) / 0.5 µs (500 kHz) / 1.0 µs
(250 kHz) / 2.0 µs (100 kHz) / 10.0 µs (10 kHz)
Control signal
No input time constant / 2 µs / 5 µs / 10 µs / 20 µs / 50 µs / 100 µs / 500 µs / 1.0
ms / 2.0 ms / 5.0 ms / 10.0 ms
Types of count operation
Enable count operation
12.6 High-speed Counter Function
12-34 WUME-GM1RTXOP-01