EasyManua.ls Logo

Panasonic KX-HDV100 - Cfg_Cyclic; Cfg_Cyclic_Intvl; Cfg_Resync_Time; Cfg_Rtry_Intvl

Panasonic KX-HDV100
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CFG_CYCLIC
Value Format BOOLEAN
Description Specifies whether the unit periodically checks for updates of
configuration files.
Value Range
Y: Enable periodic synchronization
N: Disable
Default Value
N
Web User Interface Reference Cyclic Auto Resync (Page 137)
CFG_CYCLIC_INTVL
Value Format INTEGER
Description Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
Value Range 1–40320
Default Value 10080
Web User Interface Reference Resync Interval (Page 137)
CFG_RESYNC_TIME
Value Format STRING
Description Specifies the time (hour:minute) that the unit checks for updates of
configuration files.
Value Range 00:00–23:59
Note
If
the value for this setting is any valid value other than an empty
string, the unit downloads the configuration files at the fixed
time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are
disabled.
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Default Value Empty string
Web User Interface Reference Time Resync (Page 137)
CFG_RTRY_INTVL
Value Format INTEGER
170 Administrator Guide Document Version 2015-02