Web User Interface Reference Server Address (Page 95)
TIME_SYNC_INTVL
Value Format INTEGER
Description Specifies the interval, in seconds, to resynchronize after having
detected no reply from the NTP server.
Value Range 10–86400
Default Value 60
TIME_QUERY_INTVL
Value Format INTEGER
Description Specifies the interval, in seconds, between synchronizations with the
NTP server.
Value Range 10–86400
Default Value 43200
Web User Interface Reference Synchronization Interval (Page 95)
5.3.15 Time Settings
LOCAL_TIME_ZONE_POSIX
Value Format STRING
Description Specifies a IEEE 1003.1 (POSIX)-compliant local time zone definition
(e.g., "EST+5 EDT,M4.1.0/2,M10.5.0/2").
Note
• If this parameter is specified, the following parameters are
disabled, and operation will be based on this parameter.
– TIME_ZONE
– DST_ENABLE
– DST_OFFSET
– DST_START_MONTH
– DST_START_ORDINAL_DAY
– DST_START_DAY_OF_WEEK
– DST_START_TIME
– DST_STOP_MONTH
– DST_STOP_ORDINAL_DAY
– DST_STOP_DAY_OF_WEEK
– DST_STOP_TIME
Value Range Max. 70 characters
Document Version 2015-02 Administrator Guide 193
5.3.15 Time Settings